Incidents / Incident #2807 /

IONITY fault burst open

Fault burst: 8 EVSEs across 2 stations (IONITY) within 10 min — Rovaniemi, Kilpisjärvi

Detected
21:242026-08-09
EVSEs faulted in burst
8
Stations
2
Resolved
Affected stations 2 stations
Station City EVSEs Fault events
IONITY GmbH IONITY Rovaniemi Rovaniemi 1 7
IONITY GmbH IONITY Kilpisjärvi Kilpisjärvi 1 1
Timeline faults and recoveries · UTC
21:16:13 IONITY GmbH IONITY Rovaniemi · FI*IOY*E310606 INOPERATIVE OUTOFORDER
21:16:25 IONITY GmbH IONITY Rovaniemi · FI*IOY*E310606 OUTOFORDER INOPERATIVE
21:16:35 IONITY GmbH IONITY Rovaniemi · FI*IOY*E310606 INOPERATIVE OUTOFORDER
21:17:36 IONITY GmbH IONITY Rovaniemi · FI*IOY*E310606 OUTOFORDER INOPERATIVE
21:17:54 IONITY GmbH IONITY Rovaniemi · FI*IOY*E310606 INOPERATIVE OUTOFORDER
21:20:48 IONITY GmbH IONITY Kilpisjärvi · FI*IOY*E313904 AVAILABLE OUTOFORDER
21:23:52 IONITY GmbH IONITY Rovaniemi · FI*IOY*E310606 OUTOFORDER INOPERATIVE
21:24:11 IONITY GmbH IONITY Rovaniemi · FI*IOY*E310606 INOPERATIVE OUTOFORDER